Avoid interferences due to therapeutic Monoclonal Antibody with HYDRASHIFT Portfolio.

Published date: 3/8/2021 | Modified date: 6/9/2026

About HYDRASHIFT

Therapeutic monoclonal antibody (mAb) inclusion in Multiple Myeloma treatment regimens offer patients significant improvements in clinical outcomes. daratumumab and isatuximab are human mAb targeting CD38 used in Multiple Myeloma treatment regimens.

HYDRASHIFT avoids therapeutic mAb interference on Immunofixation interpretation assays.

Key benefits

HYDRASHIFT : A simple and reliable solution to eliminate interferences from therapeutic monoclonal antibodies.
  • Distinctive shift technology

    HYDRASHIFT daratumumab and HYDRASHIFT isatuximab avoid daratumumab or isatuximab interference on HYDRAGEL IF tests.

  • Trust in the results

    HYDRASHIFT reduce the risk of incorrect IF interpretation to improve therapy monitoring.

  • Easy to implement

    Fully integrated into IF protocol without sample pre-treatment for a standardized process compliant to IMWG guidelines.

  • Follow IMWG guidelines

    Process compliant to IMWG guidelines to assess response to treatment in patient with Multiple Myeloma.

Main characteristics

Test principle

HYDRASHIFT is an immunofixation procedure performed on HYDRAGEL IF 2/4 gel and based on the creation of a mAb/ anti mAb immune complex shift mAb drug (daratumumab or isatuximab) in alpha zone.

This complex is visible in the IgG and kappa immunofixation tracks. A negative HYDRASHIFT result demonstrates the absence of endogenous M-protein.

Sample type

Serum

Performances

Sensitivity

The limit of immune complex visualized is 0.3 g/L.

Product details

  • HYDRASHIFT 2/4 daratumumab (20 tests) – P/N: 4639
  • daratumumab control – P/N: 4765
  • HYDRASHIFT 2/4 isatuximab (40 tests) – P/N: 4642
  • isatuximab control P/N: 4764

Knowledge & Science

No content available.

HYDRASHIFT test can be performed on the following instruments

Tests related to HYDRASHIFT

This section contains information intended for wide distribution and may therefore contain product details or information that is not available or valid in your country.

Please contact your local Sebia representative. Information intended for healthcare professionals.
Carefully read the instructions in the reagent package inserts and instrument manuals.

Hydrashift, avoid therapeutic mAb interference on interpretation of Immunofixation assays | Sebia